APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2564 Issued:1972-03-22
Revised:2012-07-25
Style 2564 Multiple-conductor cable using non-integral jacket.

Rating75 deg C, 125 Vac, FT2 flame.
Conductor22 AWG circuit, 22 AWG - 18 AWG grounding; consisting of twenty six of 36 AWG strands round, tinned or bare copper.
InsulationExtruded PVC, 9 mils min average, 8 mils min. at any point.
AssemblyTwo to Three Conductors twisted together with a maximum lay of Assembly 1-1/2 inches. One conductor shall be solid white or natural gray. The third, if provided, shall be green with or without a yellow stripe.
JacketExtruded PVC, 15 mils min average, 12 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseTwo Conductor Cord or Three Conductor Cord with with No. 18 AWG Grounding Conductor: "For use as listed power supply cords (permanently attached and not exceeding 8 feet in length) for curling irons, wood burning appliances, or 1/2 pound and lighter soldering irons; rated 50 watts or less." Three Conductor Cord Grounding Smaller than No. 18 AWG: "For use as listed power supply cords (permanently attached and not exceeding 8 feet in length) for 1/2 pound and lighter soldering irons where grounding is not required; rated 50 watts or less.

UL and the UL Logo are trademarks of UL LLC © 2024