APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2567 Issued:1972-04-25
Revised:2012-05-04
Style 2567 Multi-conductor cable using non-integral jacket.

Rating105 deg C, 600 Vac, Horizontal flame, Oil Res. 60 or 80 deg C, Moisture res and gas res. 75 deg C
Conductor18 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationR/C QMTT2 Extruded PVC compound suitable for Type THWN 15 mils min average, 13 mils minimum at any point.
CoveringR/C QMTT2 Extruded Nylon compound suitable for Oil and Gasoline Resistance, 4 mils minimum thickness.
AssemblyTwo to five conductors.
ShieldOver all insulated conductors.
JacketExtruded PVC, 25 mils min average, 20 mils minimum at any point.
Outer CoveringR/C QMTT2 Extruded Nylon compound suitable for Oil and Gasoline Resistance, 5 mils minimum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances and electronic equipment where exposed to temperatures not exceeding 105 deg C in dry location, 30 deg C in liquid gasoline, 75 deg C in gasoline vapor, 75 deg C in wet location, 60 deg C or 80 deg C (whichever is applicable) in oil.

UL and the UL Logo are trademarks of UL LLC © 2024