APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2568 Issued:1972-04-21
Revised:2011-09-27
Style 2568 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 300 Vac, Horizontal Flame.
Conductor30 AWG Min, solid or stranded.
InsulationExtruded PP, 40 mils minimum average thickness, 36 mils minimum thickness at any point.
AssemblyTwo-conductor.
ShieldOptional.
JacketExtruded PVC, 24 mils minimum average thickness, 19 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring for electronic use.

UL and the UL Logo are trademarks of UL LLC © 2024