APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2569 Issued:1972-04-10
Revised:2011-10-07
Style 2569 Flat Ribbon Cable.

Rating105 deg C, 600 Vac, Horizontal flame, Oil Resistant 60 deg C or 80 deg C (optional).
Conductor30 AWG - 10 AWG solid or stranded round, tinned or bare copper. All conductors same size.
InsulationPVC, 30 mils min average, 27 mils minimum at any point.
AssemblyTwo to twelve conductors. An extruded flat cable with a single row of conductors having a web between insulated conductors. The nominal and minimum insulation thickness along the ripped edges for each conductor shall be 30 and 27 mils respectively.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances not to exceed 105 deg. C; or if exposed to oil, not to exceed 60 or 80 deg. C, whichever is applicable.