			| Rating | 80 deg C, Voltage not specified, Cable flame. | 
			|  | 
			| Conductor | 40 AWG min solid or stranded round, tinned or bare copper. | 
			|  | 
			| Insulation | Labeled or complying with Manufacturer's AWM Procedure. | 
			|  | 
			| Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. | 
			|  | 
			| Shield | Optional. | 
			|  | 
			| Covering | (Optional) A 6 mil or heavier PVC covering may be extruded over the conductor assembly. | 
			|  | 
			| Jacket | PVC | 
			|  | major dia in inches | 
			|  | 0.700 or less | 30 mils min average | 24 mils minimum at any point | 
			|  | 0.701-1.000 dia | 60 avg | 48 min | 
			|  | 1.001-1.500 dia | 80 avg | 64 min | 
			|  | 
			| Standard | Appliance Wiring Material UL 758. | 
			|  | 
			| Marking | General. | 
			|  | 
			| Use | Internal wiring or External Interconnection of Electronic Equipment. | 
			|  |