| Rating | 60 deg C, 300 Vac, Horizontal flame. |
|
| Conductor | 30 AWG - 20 AWG solid or stranded round. |
|
| Insulation | Extruded Solid XLPE or Extruded Foam XLPE, 22 mils minimim average thickness, 20 mils minimum thickness at any point. See Facing Page for Compound Designation. |
|
| Assembly | Two conductors. |
|
| Shield | Required. |
|
| Jacket | Extruded PVC, 22 mils minimum average thickness, 18 mils minimum thickness at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring of electronic equipment. |
|