Rating | 80 deg C, 150 Vac, Cable flame. |
|
Conductor | 36-9 AWG, solid or stranded. |
|
Insulated Conductor | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors laid parallel or cabled together to form a flat, oval or round cable. Conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. The use of a barrier layer and/or fillers is optional. Cable may contain Labeled Flat Ribbon Style AWM which may be rolled or spiralled and formed around fillers or bunched singles. Fillers and/or tape wrap or extruded covering may be used. |
|
Covering | Optional, extruded PVC, 5 mils minimum thickness at any point, over one or more groups of conductors. |
|
Shield | Optional. The shield may be over one or more of the insulated conductors or applied between the conductor assembly and the optional covering. |
|
Jacket | Extruded PVC. |
| Diameter of cable under jacket | Minimum average thickness | Minimum thickness at any point |
| 1.000 inch or less | 30 mils | 24 mils |
| 1.001-1.500 inch | 45 mils | 36 mils |
| 1.501-2.500 inch | 60 mils | 48 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection or internal wiring of electronic equipment. |
|