APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2580 Issued:1972-05-25
Revised:2011-08-04
Style 2580 Multiple-Conductor Cable with Extruded Insulation and Extruded Non-Integral Jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded round
InsulationExtruded XLPE, 16 mils minimum average thickness, 14 mils minimum thickness at any point
AssemblyTwo or three conductors.
ShieldOptional
JacketExtruded PVC, 16 mils minimum average thickness, 13 mils minimum thickness at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024