APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2582 Issued:1972-05-19
Revised:2012-03-12
Style 2582 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating60 deg C, 150 Vac, Cable flame.
Conductor30 AWG - 16 AWG solid or stranded round, tinned or bare.
InsulationExtruded PE - POLYETHYLENE or extruded FRPE, 12 mils minimum average thickness, 10 mils minimum thickness at any point.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
Covering(Optional) A 6 mil thick or heavier PVC covering may be extruded over the conductor assembly.
JacketExtruded PVC
Diameter of core assembly under jacket (inches) ¿Minimum average thickness (mils)Minimum thickness at any point (mils)
0.395 or less3024
0.396-0.5003528
0.501-0.7005040
Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024