APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2587 Issued:1972-06-15
Revised:2012-04-20
Style 2587 Multiple-conductor cable using non-integral jacket.

Rating90 deg C, 600 Vac, Cable flame.
Conductor40 AWG min, solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. May use same or mixed AWG size.
CoveringOptional, extruded PVC, a 6 mils or heavier, may be extruded over the conductor assembly.
ShieldOptional.
JacketExtruded PVC.
Dia of round assembly under jacket inchesMinimum average thickness milsMinimum at any point mils
0.700 or less3024
0.701-1.0006048
1.001-1.5008064
1.501-2.50011088
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring.