APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2588 Issued:1972-06-16
Revised:2012-04-24
Style 2588 Multiple-conductor cable using non-integral jacket.

Rating60 deg C, 30 Vac, 60 deg C Wet.
ConductorStranded, 26 AWG (7/34AWG), 20 AWG (10/30AWG), 18 AWG (16/30AWG).
InsulationExtruded PVC, 10 mils min average, 8 mils minimum at any point. R/C QMTT2 compounds suitable for Type THWN, or see Facing page.
AssemblyNine conductors, consisting of three 26 AWG, four 20 AWG, and two 18 AWG. Conductors are cabled together with a barrier layer of Polyester tape.
CoveringExtruded foamed PE, 105 mils min. at any point
JacketExtruded TPU, 25 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use as floatation cable where the acceptability of the combination has been determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024