Rating | 80 deg C, No voltage assigned, Horizontal flame. |
|
Conductor | 30 AWG - 16 AWG, solid or stranded. |
|
Insulation | Extruded PVC, 10 mils minimum average thickness, 9 mils minimum thickness at any point. |
|
Assembly | Two to three conductors. |
|
Shield | Optional. |
|
Jacket | Extruded PVC, 10 mils minimum average thickness, 8 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Electronic Equipment where not subjected to mechanical damage.
|
|