APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2591 Issued:1972-07-14
Revised:2011-11-02
Style 2591 Multiple-conductor cable using non-integral jacket.

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor27 AWG - 16 AWG, solid or stranded.
InsulationExtruded PE or extruded FRPE, 18 mils minimum average thickness, 16 mils minimum thickness at any point.
AssemblyTwo conductors.
ShieldOver each insulated conductor.
JacketExtruded PVC, 26 mils minimum average thickness, 21 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.