Rating | 60 deg C, voltage not specified, FT2 flame. |
|
Conductor | 22 AWG - 20 AWG, stranded. |
|
Insulation | Sub assembly A - Extruded PVC, 15 mils thickness which complies with Section 1 . Subassembly B - Extruded foamed PP or extruded foamed PE, 58 mils thickness. |
|
Assembly | Multi conductors. Subassembly A - 20 AWG stranded, tinned copper conductor with PVC insulation. Subassembly B - 22 AWG stranded copper conductor with foamed PP or PE insulation; copper braid shield; and with an optional PVC jacket, 15 mils thickness. 12 of Subassembly A cabled around one of Subassembly B with an overall polyester tape (0.001 in) wrap. |
|
Shield | Optional. |
|
Jacket | Extruded PVC, 32 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | TV Camera Cable. |
|