APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2599 Issued:1972-09-20
Revised:2011-09-27
Style 2599 Laminated flat ribbon cable

Rating80 deg C, 300 Vac, Horizontal Flame.
Conductor30 AWG - 16 AWG, solid or stranded.
Insulated ConductorLabeled or complying with manufacture's AWM procedure.
Assembly2-100 insulated singles or twisted pair, laid parallel in one plane, laminated between 2 sheets of extruded PVC. May include mixed AWG sizes. Minimum 24 mils between insulated conductors, 12 mil minimum edge width.
JacketLaminated PVC sheets, 5 mils minimum average thickness, 4 minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.