APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2605 Issued:1972-10-30
Revised:2012-03-22
Style 2605 Multiple-conductor cable using non-integral jacket

Rating75 deg C, 125 Vac, Horizontal flame.
Conductor22 AWG consisting of 36 AWG or smaller stranded, bare copper.
InsulationPVC, 9 mils min average, 8 mils min. at any point
AssemblyTwo conductors twisted together with a maximum lay of 1-1/2 inches. One conductor shall be solid white or natural gray.
JacketPVC, 25 mils min average, 22 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use as listed power supply cords (permanently attached and not exceeding 8 feet in length) for double insulated curling irons, wood burning appliances, or 1/2 pound and lighter soldering irons; rated 50 watts or less.