| Rating | 60 deg C, 300 Vac, horizontal flame. |
|
| Conductor | No. 30 AWG - 20 AWG solid or stranded. |
|
| Insulation | Cellular XLPE, 15 mils min average, 13 mils minimum at any point. |
|
| Assembly | Two, three or four conductors twisted or parallel, lay unspecified, fillers optional. |
|
| Shield | Optional. |
|
| Jacket | Extruded PVC, 15 mils min average, 12 mils minimum at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring. |
|