APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2611 Issued:1973-01-30
Revised:2015-02-26
Style 2611 Multiple Conductor with Extruded Insulation and Extruded Non-Integral Jacket.

Rating60, 80, 90, 105 deg C, 300 Vac, Horizontal flame.
Conductor34 AWG - 16 AWG solid or stranded round.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyTwo through six conductors
ShieldShielding over conductor insulation shall consist of 42-30 AWG tinned or untinned copper strands applied as a wrap or braid or a wrap of aluminum faced Polyester tape with a parallel uninsulated drain wire.
JacketExtruded PVC, 16 mils minimum average thickness, 13 mils minimum thickness, at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024