|
Rating | 105 deg C, 30 Vac, Cable flame. |
|
Conductor | 40 AWG minimum, solid or stranded. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure except that Styles rated 30 Volts for Class 2 operation may not be used. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Covering | Optional. Extruded PVC, a 6 mils or heavier, may be extruded over the conductor assembly. |
|
Shield | Optional. |
|
Jacket | Extruded PVC. |
| Diameter of core assembly under jacket inches | Minimum average thickness mils | Minimum thickness at any point mils |
| 0.425 or less | 30 | 24 |
| 0.426-0.700 | 45 | 36 |
| 0.701-1.000 | 60 | 48 |
| 1.001-1.500 | 80 | 64 |
| 1.501-2.500 | 110 | 88 |
| 2.501 and larger | 140 | 112 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External wiring. |
|