APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2620 Issued:1973-04-03
Revised:2012-10-24
Style 2620 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG, solid or stranded.
InsulationExtruded XLPE, 30 mils minimum average thickness, 28 mils minimum thickness at any point.
AssemblyTwo conductors. Lay parallel.
ShieldOptional. Over each conductor.
JacketExtruded PVC, 30 mils minimum average thickness. 28 mils minimum thickness at any point after rip.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.