APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2621 Issued:1973-05-30
Revised:2012-05-03
Style 2621 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 20 AWG solid or stranded.
InsulationFoamed XLPE, 15 mils min average thickness, 13 mils minimum thickness at any point.
AssemblyTwo to four conductors parallel or twisted, lay unspecified, fillers optional.
ShieldOptional.
JacketExtruded PVC, 15 mils min average thickness, 13 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.