APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2626 Issued:1973-04-17
Revised:2019-11-06
Style 2626 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 30 Vac, Cable flame.
InsulationLabeled or complies with manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
Covering(Optional) A 6 mil or heavier Extruded PVC covering may be over the conductor assembly.
JacketExtruded PVC
major dia in inches
0.425 or less30 mils minimum average thickness24 mils minimum thickness at any point
0.426-0.700 dia45 avg36 min
0.701-1.000 dia60 avg48 min
1.001-1.500 dia80 avg64 min
1.501-2.500 dia110 avg88 min
2.501 dia and larger140 avg112 min.
- Major dia if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or External interconnection in Class 2 Circuits.