Rating | 80 deg C, Voltage not specified, Horizontal flame (construction A) Cable flame (construction B). |
|
Conductor | 32 AWG - 20 AWG, solid or stranded, copper, copper-clad steel, copper alloy, bare, tinned or silver-coated, having a minimum of 40 percent conductivity. |
|
Insulation | Extruded XLPE or extruded foamed XLPE, 15 mils thickness. |
|
Assembly | Multiple conductors. Over the conductors shall be applied a spiral wrap of XLPE or foamed XLPE thread nominally 15 mils in diameter, approximately 1/2 inch between turns. This assembly shall be enclosed with an XLPE or foamed XLPE tube having an approximate 15 mils thickness. Over this is applied a wrap of aluminum-faced PET tape with a drain wire under the tape. The length of lay of the twisted conductors is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving or braid; paper; nylon; PET; or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional. |
|
Jacket | Extruded PVC. |
| Construction A | | |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.425 inch or less | 35 mils | 28 mils |
| 0.526-0.700 inch | 60 mils | 48 mils |
| 0.701-1.500 inch | 80 mils | 64 mils |
| 1.501-2.500 inch | 110 mils | 88 mils |
| 2.501 inch and larger | 140 mils | 112 mils |
| #Construction B, , ; Diameter of core assembly under jacket, Minimum average thickness, Minimum thickness at any point; 0.700 inch or less, 60 mils, 48 mils; 0.701-1.500 inch, 80 mils, 64 mils; 1.501-2.500 inch, 110 mils, 88 mils; 2.501 inch and larger, 140 mils, 112 mils# |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | - Construction A - Internal wiring. - Construction B - External wiring. |
|