Rating | 90 deg C, 30 Vac, Cable flame. |
|
Conductor | 40 AWG minimum solid or stranded round. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Covering | (Optional) A 6 mil or heavier PVC covering may be extruded over the conductor assembly. |
|
Shield | Optional. |
|
Jacket | Extruded PVC major dia in inches of 0.425 or less, 30 mils min average, 24 mils minimum at any point; 0.426-0.70 dia, 45 avg, 36 min; 0.701-1.000 dia, 60 avg, 48 min; 1.001-1.500 dia, 80 avg, 64 min; 1.501-2.500 dia, 110 avg, 88 min; 2.501 dia and larger, 140 avg, 112 min. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External Wiring. |
|