APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2643 Issued:1973-07-31
Revised:2018-01-16
Style 2643 Flat Cable.

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor32 AWG - 10 AWG round or flat, nickel, silver, gold, or tin plated or bare copper, or polyurethane coated copper. May use same or mixed AWG size. Minimum thickness of 1.5 mils; maximum thickness of 20.0 mils. Minimum width of 10 mils and maximum width of 350 mils.
InsulationOn each side of the conductors is 3.5 mils minimum of PVC adhesive or 1.5 mils minimum of polyester adhesive bonded to biaxially oriented Polyethylene Terephthalate (PET) with minimum average thickness 2.0 mils, minimum thickness at any point 1.5 mils.
AssemblyTwo through 150 conductors may be straight or irregular shaped and laid parallel and in one plane. Minimum 16 mils insulation width on outside edges of conductors and 16 mils minimum insulation width between adjacent conductors. Length of insulated conductors not specified.
ShieldOptional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024