|
Rating | 80 deg C, 300 Vac, Cable flame. |
|
Conductor | 36 AWG min - 6 AWG. Copper, copper clad steel, or copper alloy, bare or coated (tin or silver), solid or stranded. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with no more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or a thermoplastic- tape wrap. Such a barrier layer would serve to protect the cable during further processing, and would be applied immediately over the twisted assembly of individual conductors or groups of conductors or over the shield, if provided. |
|
Shield | Optional. |
|
Jacket | Extruded PVC; |
| dia in inches |
| 0.700 or less | 30 mils minimum average thickness | 24 mils minimum thickness at any point |
| 0.701-1.000 dia | 45 avg | 36 min |
| 1.001-1.500 dia | 60 avg | 48 min |
| 1.501-2.500 dia | 80 avg | 64 min |
| 2.501 dia and larger | 110 avg | 88 min |
| 4.001 dia and larger | 140 ave | 112 min. |
| |
| - Major diameter if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External wiring. |
|