APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2659 Issued:1973-09-19
Revised:2012-04-11
Style 2659 Multiconductor Cable With Extruded Non-Integral Jacket.

Rating60 deg C, 50 Vac, Horizontal Flame.
Conductor27 AWG - 16 AWG, Solid or Stranded Round.
InsulationExtruded PE or Extruded FRPE - 12 mils minimum average, 10 mils minimum at any point.
AssemblyFour conductors. Two conductors are twisted together and the other two are individually shielded and cabled together with the twisted pair. The length of lay is not specified. Fillers may be used but are not required.
ShieldOptional.
JacketExtruded PVC, 30 mils minimum average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of low energy circuits of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024