APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2660 Issued:1973-09-20
Revised:2019-11-06
Style 2660 Multiple-conductor cable using non-integral jacket.

Rating60 deg C, voltage not specified, Cable flame.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyTwo or more twisted insulated singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional.
ShieldOptional.
Covering(Optional) Extruded PVC, nominal 15 mil covering over the conductor assembly
JacketPVC
dia in inches
0.700 or less30 mils min average24 mils minimum at any point
0.701-1.000 dia60 avg48 min
1.001-1.500 dia80 avg64 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024