Rating | 80, 90 or 105 deg C, 300 Vac, Cable Flame. |
|
Conductor | 40 AWG - 6 AWG. Solid or stranded. |
|
Insulated Conductor | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two or more insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with no more than three rows of single insulated conductors or groups of insulated conductors. The length of lay of the twisted or groups insulated conductors is not specified. Fillers may be used in the cable but are not required. A barrier layer, if employed, may be fibrous wrap serving, or braid, paper, nylon, oriented polyethylene terephthalate, or thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual insulated conductors or groups of insulated conductors or over the shield, if provided. Cable may employ optional steel strength member. |
|
Covering | Optional. |
|
Shield | Optional. |
|
Jacket | Extruded PVC. |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701-1.000 | 45 mils | 36 mils |
| 1.001-1.500 | 60 mils | 48 mils |
| 1.501-2.500 | 80 mils | 64 mils |
| 2.501-4.000 | 110 mils | 88 mils |
| 4.001 inch or greater | 140 mils | 112 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of electronic equipment. |
|