APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2662 Issued:1973-09-21
Revised:2013-01-30
Style 2662 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 600 Vac, Cable flame.
Conductor33 AWG - 10 AWG.
Insulated ConductorLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together to form a flat cable with no more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or a thermoplastic- tape wrap. Such a barrier layer would serve to protect the cable during further processing, and would be applied immediately over the twisted assembly or individual conductors or groups of conductors.
ShieldOptional.
JacketExtruded PVC.
Diameter of cable under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less60 mils48 mils
0.701-1.500 inch80 mils64 mils
1.501-2.500 inch110 mils88 mils
2.500 inch and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment.