APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2666 Issued:1973-09-14
Revised:2012-07-25
Style 2666 Parallel Cable with Extruded Insulation.

Rating105 deg C, 30 Vac, Horizontal flame.
ConductorNo. 33 AWG - 27 AWG solid or stranded round, nickel, silver, nickel- or silver-plated copper.
InsulationFEP, 3 mils min average.
AssemblyTwo or three conductors laid parallel in one plane.
CoveringOptional - coating of polyimide or amide/imide over one or more of the conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.