Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 26 AWG - 16 AWG solid or stranded round. |
|
Insulation | Extruded PE or Extruded FRPE, 15 mils min average, 13 mils minimum at any point. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layerand/or fillers are optional. May use same or mixed AWG size. |
|
Covering | (Optional) A 6 mil or heavier PVC covering may be extruded over the conductor assembly. |
|
Shield | Optional. |
|
Jacket | Extruded PVC major dia in inches of 0.350 or less, 15 mils min average, 12 mils minimum at any point; 0.351-0.700 dia, 30 avg,24 min; 0.701-1.000 dia, 45 avg, 36 min; 1.001-1.500 dia, 60 avg, 48 min. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|