APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2673 Issued:1973-10-31
Revised:2011-08-11
Style 2673 Multiple-Conductor with Extruded Insulation and Non-Integral Jacket

Rating60 deg C, Voltage not specified.
Conductor30 AWG - 22 AWG solid or stranded
InsulationLabeled styles 1375 and 1095
AssemblyMulti conductors. All conductors and conductor groups are cabled together. Two Style 1375, 30 AWG with 22 mils wall insulation and 11 mil jacket. Two Style 1095, AWG. Two Style 1095, 24 AWG cabled with 22 AWG bare copper drain wire and wrapped with aluminum faced Polyester tape.
JacketPVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseTV Camera Cable.