APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2674 Issued:1973-12-04
Revised:2012-03-12
Style 2674 Parallel Cable with Extruded Insulation Using Extruded Non-Integral Jacket

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded round, tinned or bare.
InsulationExtruded PE, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyTwo to six conductors.
ShieldOptional.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point. May employ a web.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.