APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2675 Issued:1973-11-09
Revised:2012-02-02
Style 2675 Multi-conductor Cable with Extruded Non-Integral Jacket.

Rating60 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complying with Manufacture's AWM Procedure.
AssemblyTwenty-eight conductors. C1, C2, and C3 -- Three 28 AWG Style 1589 with 7 mils wall thickness of extruded PP, twisted together with copper braid over each group. The groups are then twisted together. 1, 2, and 3 -- Twelve conductors consisting of seven 26 AWG Style 1061 and five 28 AWG in 3 groups of 4 conductors. Each group twist together. 4, 5, and 6 -- 18 AWG Style 1061. 7, 8, 9, and 10 -- 20 AWG Style 1061 conductors 1 through 10 are cabled around center group of C1, C2, and C3, then covered with a cotton serve, or polyester tape, paper tape and/or fiberglass tape.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInterconnecting Cable for Medical Instruments.