Rating | 60 deg C, 60 Vac, Cable flame. |
|
Conductor | 32 AWG min., Copper, Copper Clad Steel, or Copper Alloy, Bare or Coated (tin or silver), solid or stranded. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. Designations of all styles of individual conductors used in making up the cable assembly shall be available. |
|
Assembly | Two or more individually insulated conductors or groups of Assemblyinsulated conductors cabled together. Length of lay of the twisted conductors or groups not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly or individual conductors or groups of conductors. |
|
Shield | Optional. |
|
Jacket | Extruded XLPO-THERMOSET POLYOLEFIN |
| dia in inches |
| 0.700 or less | 60 mils min average | 48 mils minimum at any point |
| 0.701-1.500 dia | 80 avg | 64 min |
| 1.501-2.500 dia | 110 avg | 88 min |
| 2.500 dia and larger | 140 avg | 112 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | For use with electronic computers and business machines, Class 2 wiring systems only. |
|