APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2681 Issued:1974-02-05
Revised:2019-10-11
Style 2681 Multiple-conductor cable using non-integral jacket

Rating80 deg C, No Voltage Assigned, Horizontal flame.
Conductor32 AWG - 16 AWG solid or stranded.
InsulationExtruded XLPVC, 10 mils min average, 9 mils minimum at any point.
AssemblyTwo to twenty conductors.
ShieldOptional - one or more conductors.
JacketExtruded XLPVC
dia in inchesmin average in milsminimum at any point in mils
0 - 0.3500.351 -108
0.700 dia15 ave13 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024