APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2682 Issued:1974-03-20
Revised:2012-02-24
Style 2682 Parallel cable with extruded integral insulation and jacket.

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 24 AWG, solid or stranded. One or more selected conductors may be in electrical contact with ground plane.
Misc.Ground Plane - Expanded copper, thickness 0.003 in. min.
InsulationExtruded PVC, backing layer, 6 mils minimum average thickness; intermediate layer, 6 mils minimum average thickness; top layer, 6 mils minimum average thickness. Top layer may form ridges over conductors. Sections of the cable may be split into singles or groups of conductors.
AssemblyEight to seventy-five conductors. PVC, min thickness, backing layer, 6 mils, intermediate 6 mils, top layer 6 mils. Top layer may form ridges over conductors. Sections of the cable may be split into singles or groups of conductors. The insulation may be laminated or extruded
ShieldOptional.
CoveringOptional - Extruded PVC, 5 mils minimum thickness at any point, 80 mils maximum.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electrical Equipment Such as Electronic Computers and Electric Business Machines.