APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2690 Issued:1974-05-10
Revised:2012-05-04
Style 2690 Laminated Flat Ribbon Cable.

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 4 AWG, flat, min width 20 mils, max width 2-0.5 inches, min thickness 1 mil, max thickness 15 mils
InsulationNon-extruded PETP tape, 3 mils min average.
AssemblyTwo through 100 conductors. PETP tape - On each side of the conductors a 2 mils min at any point wall of PETP tape with a min 1 mil polyester adhesive backing bonded together. Min 25 mils insulation width on outside edges of conductors and 20 mils min width insulation between adjacent conductors. Length of insulated conductors not specified.
ShieldOptional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024