APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2692 Issued:1974-06-12
Revised:2012-01-19
Style 2692 Laminated flat ribbon cable

Rating105 deg C, 300 Vac, Horizontal Flame.
Conductor30 AWG - 16 AWG, solid or stranded.
InsulationLabeled or complying with manufacture's AWM Procedure.
Assembly2 - 100 conductors. Insulated singles or twisted pair, spaced 50 mils min. parallel in one plane, laminated between 2 sheets of extruded PVC. May include mixed AWG sizes. Manufacturer shall maintain a record of all insulated singles used in each cable.
CoveringTwo laminated sheets of extruded PVC, 10 mils minimum average thickness, 8 mils minimum thickness at any point. Minimum 10 mil from edges to the first conductor.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.