Rating | 105 deg C, 300 Vac, Horizontal Flame. |
|
Conductor | 30 AWG - 16 AWG, solid or stranded. |
|
Insulation | Labeled or complying with manufacture's AWM Procedure. |
|
Assembly | 2 - 100 conductors. Insulated singles or twisted pair, spaced 50 mils min. parallel in one plane, laminated between 2 sheets of extruded PVC. May include mixed AWG sizes. Manufacturer shall maintain a record of all insulated singles used in each cable. |
|
Covering | Two laminated sheets of extruded PVC, 10 mils minimum average thickness, 8 mils minimum thickness at any point. Minimum 10 mil from edges to the first conductor. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment. |
|