Rating | 80 deg C, 300 Vac, Horizontal Flame. |
|
Conductor | 30-16 AWG, Solid or Stranded Round. |
|
Insulation | Integral with Jacket. Labeled or complying with Manufacture's AWM Procedure. |
|
Assembly | Two to 200 insulated singles, twisted pair triads or quads laid parallel in one plane, intermittently or continuously bonded together or bonded to a PVC-Polyester or PVC covering in such a fashion to form a flat ribbon type cable. May include mixed AWG sizes. Manufacturer shall maintain a record of all singles used in each cable. Sections may be slit into singles or groups of conductors. Insulated conductors with optional covering, optional shield and optional covering. |
|
Inner Covering | Optional - Extruded PVC or One or two sheets of PVC or polyester/PVC laminated film, each sheet is 2 mil minimum at any point, laminated over the cable assembly. Film covering may be perforated. Hole diameter and pattern is not specified. |
|
Shield | Optional. |
|
Outer Covering | Optional - Extruded PVC, 5 mils minimum at any point, 80 mils maximum. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|