APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2697 Issued:1974-06-18
Revised:2012-07-01
Style 2697 Laminated Flat Cable.

Rating80 deg C, 300 Vac, Horizontal Flame.
Conductor30-16 AWG, Solid or Stranded Round.
InsulationIntegral with Jacket. Labeled or complying with Manufacture's AWM Procedure.
AssemblyTwo to 200 insulated singles, twisted pair triads or quads laid parallel in one plane, intermittently or continuously bonded together or bonded to a PVC-Polyester or PVC covering in such a fashion to form a flat ribbon type cable. May include mixed AWG sizes. Manufacturer shall maintain a record of all singles used in each cable. Sections may be slit into singles or groups of conductors. Insulated conductors with optional covering, optional shield and optional covering.
Inner CoveringOptional - Extruded PVC or One or two sheets of PVC or polyester/PVC laminated film, each sheet is 2 mil minimum at any point, laminated over the cable assembly. Film covering may be perforated. Hole diameter and pattern is not specified.
ShieldOptional.
Outer CoveringOptional - Extruded PVC, 5 mils minimum at any point, 80 mils maximum.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.