APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2703 Issued:1974-07-19
Revised:2012-04-20
Style 2703 Bonded or laminated flat ribbon cable.

Rating80 deg C, 300 Vac, VW-1 flame.
Conductor28 AWG - 16 AWG solid or stranded round.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyThree conductors laid parallel and in one plane. Same or mixed AWG. Nominal 0.25 in. between insulated conductors with 20 mil web thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Radio and Television Receivers.