APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2707 Issued:1974-09-09
Revised:2011-08-11
Style 2707 Bonded Flat Ribbon Cable

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor32 AWG - 14 AWG solid or stranded. 2-14 AWG flat conductors; 32-20 AWG round conductors.
InsulationPET, PETP, 3 mils minimum average thickness.
AssemblyTwo to 100 conductors laid parallel and in one plane. One each side of the conductors, 3 mils minimum thickness at any point, Oriented Polyethylene Terephthalate ("Mylar") bonded together with minimum average thickness 15 mil insulation width on outside edges of conductors and 15 mil minimum width insulation between adjacent conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment such as computers and business machines and appliances.

UL and the UL Logo are trademarks of UL LLC © 2024