APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2714 Issued:1975-01-24
Revised:2013-02-07
Style 2714 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 125 Vac, Horizontal flame.
Conductor30 AWG - 20 AWG, stranded. May include mixed AWG sizes.
InsulationExtruded PVC, 12 mils minimum average thickness, 10 mils minimum thickness at any point.
AssemblyTwo to eight conductors wound in retractile form.
JacketExtruded PVC, 60 mils minimum average thickness, 48 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal ac interconnecting Cable for Medical and Dental Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024