APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2717 Issued:1975-01-03
Revised:2012-04-23
Style 2717 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, Voltage not specified, Horizontal flame.
Conductor22 AWG, stranded.
InsulationExtruded PP, 8 mils minimum average thickness, 5 mils minimum thickness at any point, or extruded FRPE.
AssemblyFour conductors.
ShieldConductors grouped in pairs with shield over each pair a clear Polyester Wrap is applied over shield of paired conductor with an over-all shield. Each shield has a 24 AWG or 22 AWG stranded bare drain wire.
JacketExtruded PVC, 24 mils minimum average thickness, 19 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring of Medical Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024