APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2721 Issued:1975-03-12
Revised:2012-07-26
Style 2721 Multi-conductor, helically coiled cable with non-integral jacket.

Rating80 deg C, 300 Vac, Cable flame.
InsulationLabeled or compying with Manufactur's AWM Procedure. A record of all styles of individual singles used in each cable shall be maintained.
AssemblyMulti conductors. Individually insulated singles or groups of singles cabled together into a round cable. Lay not specified. Fillers or wraps optional.
ShieldNot permitted.
JacketExtruded PVC, cable dia. in mils of 0.425 or less, 30 mils min average, 24 mils minimum at any point, 426 - 700, 60 avg,48 min.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnecting of medical or electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024