APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2725 Issued:1975-05-02
Revised:2013-02-25
Style 2725 Multiple-conductor cable using non-integral jacket

Rating60 or 80 deg C, 30 Vac, Horizontal flame.
Insulated ConductorLabeled or complies with manufacturer's AWM Procedure.
AssemblyTwo to four parallel, or two or more twisted insulated singles or groups of twisted singles twisted together or groups of twisted singles may be laid parallel to form flat or oval cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. Diameter of assembly under jacket one inch maximum.
ShieldOptional.
JacketExtruded PVC, 9 mils minimum average thickness, 7 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment in Class 2 systems only.