APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2737 Issued:1975-08-18
Revised:2012-03-15
Style 2737 Bonded Non-Extruded Flat Ribbon Cable

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor32 AWG - 24 AWG Flat or round, unplated or tin plated
InsulationExtruded PET, PETP, 4 mils minimum average thickness, 1.5 mils minimum thickness at any point.
AssemblyTwo to 150 conductors laid parallel and in one plane. Flat conductor thickness 1-6 mils and width 26-65 mils. PVC bonded together with minimum 10 mils insulation thickness between conductors and minimum 20 mils insulation thickness between outer conductors and edge.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances.