Rating | 60 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 32 AWG - 14 AWG, solid or stranded. Optional - 2 mils maximum wall thickness of an alkyd enamel or polyurethane-nylon enamel over the copper conductors. |
|
Insulation | Extruded PE, extruded FRPE, extruded XLPE, extruded XLFRPE, extruded foamed PE, extruded foamed FRPE, extruded foamed XLPE, extruded foamed XLFRPE, extruded PP, extruded foamed PP, extruded low density PTFE, 7 - 100 mils minimum thickness. |
|
Shield | Optional. |
|
Assembly | Two to 100 insulated conductors, bonded together to form a flat cable. May use same or mixed AWG size. Optional - Alignment rib may be provided on outside conductors. Minimum thickness at any point may be reduced to 3 mils where the drain wire contacts the jackets. Uninsulated copper conductors may be employed as stress members in lieu of the insulated conductors. |
|
Shield | Optional - Over cable assembly. |
|
Covering | Optional - Extruded PVC, 5 - 80 mils minimum thickness at any point. Over cable assembly or shield. |
|
Jacket | Extruded PVC, 9 mils minimum average thickness, 7 mil minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Electronic Equipment in Class 2 Circuits Only. |
|