APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2742 Issued:1975-08-18
Revised:2012-04-18
Style 2742 Multiple conductor with extruded insulation or other-than-extruded insulation.

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 12 AWG, round or flat, straight or irregular shaped laid parallel in one plane.
InsulationOn each side of the flat conductors 3.0 mils minimum of extruded PVC, or 1.5 mils minimum of non-extruded PETP tape bonded with 1.5 mils minimum polyester adhesive. Insulation width on the outside edges of the conductor not less than 16.0 mils and not less than 16.0 mils width between adjacent conductors.
AssemblyTwo through 150 conductors laid parallel in one plane. Length of insulated conductors not specified.
ShieldOptional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment (such as computers and business machines) and appliances.

UL and the UL Logo are trademarks of UL LLC © 2024